6600 Series
Programmable AC Power Source
(Switching) |
6700 Series
Programmable AC Power Source
(Linear) |
6800 Series
Digital AC Power Source |
6900 Series
AC Power
Source |
 |
 |
 |
 |
 |
Utilize advance PWM technology with
switching amplifier design, the
efficiency up to at least 80%. |
 |
Adopt
direct couple output technology,
compact in size and light weight. As
small as 22.2cm height and 65kG
weight for capacity of 4KVA. |
 |
Large
240 X 64 Graphic LCD display for
readouts of V, F, Arms, Apeak, P, PF
and Time. |
 |
Adjust voltage/frequency setting via
Rotary Knob when output is turn ON. |
 |
Programmable design: Capable to set
the starting and ending
angle/Surge/Drop cycle. |
 |
Programmable 50 memories, 9 steps
per memory, for interconnection
between each step to simulate
different testing condition of the
DUT. |
 |
Capable to store and recall 50
memories, as well as varying
voltage/frequency when output is
turn ON. |
 |
For
Aging or Life test on DUT, the user
able to change the timer either in
second, minute or hour. |
 |
High
crest factor . Capable to withstand
inrush current >=3 times of rate
current. |
 |
Able
to protect against false judgment on
high inrush current loads for
1000mS. |
 |
There
is a unique feature that able to
turn on high inrush current loads
such as motors and compressors. |
 |
Optional Remote I/P (includes 7
memories recall) interface for
automatic control or GPIB/RS232
nterface control. |
 |
Protections and alerts for overload,
short circuit, over voltage, over
power and over temperature. |
 |
Optional DC output 0 - 400V. |
|
 |
Large
240 X 64 Graphic LCD display for
readouts of V, F, Arms, Apeak, P, PF
and Time |
 |
Adjust voltage/frequency setting via
Rotary Knob when output is turn ON. |
 |
Programmable design: Capable to set
the starting and ending
angle/Surge/Drop cycle. |
 |
Programmable 50 memories, 9 steps
per memory, for interconnection
between each step to simulate
different testing condition of the
DUT. |
 |
Capable to store and recall 50
memories, as well as varying
voltage/frequency when output is
turn ON. |
 |
For
Aging or Life test on DUT, the user
able to change the timer either in
second, minute or hour. |
 |
Sophisticated and compact design –As
small as 2U (8.9cm) height for
capacity of 1KVA |
 |
Optional high resolution measurement
of 0.1mA/0.01W for cost effective
solution as no additional Power
Meter needed |
 |
There
is a unique feature that able to
turn on high inrush current loads
such as motors and compressors |
 |
Optional remote I/P (includes 7
memories recall) interface for
automatic control or GPIB/RS232
interface control |
 |
Protections and alerts for overload,
short circuit, over voltage and over
temperature |
 |
Option: Voltage 0 ~ 600V and
Frequency 45.0 ~ 999.9Hz |
|
 |
Linear amplifying design with low
distortion and yet high stability. |
 |
Sophisticated and compact design –As
small as 2U (8.9cm) size for
capacity of 1KVA |
 |
Adjustable output voltage 0 ~ 300Vac
and Frequency 45 ~ 500Hz |
 |
Optional resolution of 0.1mA/0.01W
for cost saving as no additional
Power Meter needed |
 |
Unique regulation function in
providing capability to turn on high
inrush current loads such as motors
and compressors |
 |
4
modules of green LED display –For
measurement display of Frequency,
Voltage, Current and Power/Power
Factor |
 |
High
Crest Factor, capable to withstand
inrush current > 4 times of rated
current and protect against false
judgement on high inrush current
loads for 1000mS |
 |
Optional Remote Memory control
(M1-M7) for quick output control |
 |
Temperature and speed controlled fan
to lessen noise produced |
 |
Capacity: 500VA ~ 4KVA |
 |
Option: Voltage 0 ~ 600V and
Frequency 45.0 ~ 999.9Hz |
|
 |
Adjustable AC output voltage 0~300V
/ frequency 40~450HZ and DC output
0~400V |
 |
4
groups of digital LED displays-----
voltage, current, frequency and
power or power factor |
 |
3
memories. Able to store voltage,
frequency and current high limit
setting. |
 |
High
crest factor . Capable to withstand
inrush current >=3 times of rate
current. |
 |
Able
to protect against false judgement
on high inrush current loads for
1000mS |
 |
Utilize PWM technology with
switching amplifier design, the
efficiency up to at least 80% |
 |
Protection circuits for over current
, overpower, over temperature and
over voltage . |
 |
Compact in size and light weight. As
small as 2U(8.9cm) height for
capacity for 500~2000VA. |
|
 |
 |
 |
 |
|
Broşür için
üstteki ikona tıklayınız |
Broşür için
üstteki ikona tıklayınız |
Broşür için
üstteki ikona tıklayınız |
Broşür için
üstteki ikona tıklayınız |
|
|
|
|
|
|
6300 Series
High Power Programmable 3Phase AC Power
Source(Switching) |
6400 Series
High Power Digital
AC Power Source(Switching)
|
6500 Series
High Power Programmable 1 Phase
AC Power Source(Switching) |
 |
 |
 |
 |
Programmable Three phase output |
 |
Utilize PWM technology with
switching amplifier design |
 |
Adjustable Output voltage 0 ~ 300Vac
and Frequency 47 ~ 63Hz |
 |
4
groups of digital LED displays -
Frequency, Voltage, Current and
Power or Power Factor |
 |
Waveform distortion less than 1% on
resistance load |
 |
Crest
factor of 3:1 |
 |
Storage up to 8 memories with 5
steps per memory |
 |
Programmable high/low limit settings
on voltage, frequency, current,
power and power factor |
 |
Auto
loop cycle, up to 999900 cycles |
 |
Selectable test time in seconds,
minutes or hours |
 |
Fast
recovering time, 2 milliseconds |
 |
Line
and load regulation circuits to
provide consistent set output
voltage when input voltage varies
and high inrush current UUT for
example motors an compressors |
 |
Line
and load regulation maintains the
output voltage within 0.5% of
setting |
 |
Capable to withstand inrush current
up to 3 times of rated current |
 |
High
power, compact design and light in
weight |
 |
Built-in
PLC remote interface control,
including TEST/RESET and recall 3
memories setting, P1, P2 and P3. |
 |
"Protection
circuits for overload, short circuit
and over temperature" |
 |
Built-in
Input Power Factor Correction for
three phase input only |
 |
Front
panel software calibration |
 |
Universal output sockets (15A) on
front panel |
 |
Optional GPIB/RS232 Interfaces |
|
 |
Single phase output |
 |
Utilize PWM technology with
switching amplifier design |
 |
Adjustable Output voltage 0 ~ 300Vac
and Frequency 47 ~ 63Hz |
 |
Waveform distortion less than 1% on
resistance load |
 |
Crest
factor of 3:1 |
 |
Able
to store high/low limit settings on
voltage,frequency and current high
limit setting |
 |
4
groups of digital LED displays -
Frequency, Voltage, Current and
Power or Power Factor |
 |
Fast
recovering time, 2 milliseconds |
 |
Line
and load regulation circuits to
provide consistent set output
voltage when input voltage varies
and high inrush current UUT for
example motors an compressors |
 |
Line
and load regulation maintains the
output voltage within 0.5% of
setting |
 |
Capable to withstand inrush current
up to 3 times of rated current |
 |
High
power, compact design and light in
weight |
 |
Built-in
PLC remote interface control,
including TEST/RESET and recall 3
memories setting, M1, M2 and M3. |
 |
Protection circuits for overload,
short circuit and over temperature |
 |
Built-in
Input Power Factor Correction (PFC)
for three phase input only |
 |
Front
panel software calibration |
 |
Universal output sockets (15A) on
front panel |
|
 |
Programmable Single phase output |
 |
Utilize PWM technology with
switching amplifier design |
 |
Adjustable Output voltage 0 ~ 300Vac
and Frequency 47 ~ 63Hz |
 |
Waveform distortion less than 1% on
resistance load |
 |
Crest
factor of 3:1 |
 |
4
groups of digital LED displays -
Frequency, Voltage, Current and
Power or Power Factor |
 |
Storage up to 8 memories with 5
steps per memory |
 |
Programmable high/low limit settings
on voltage,frequency, current, power
and power factor |
 |
Auto
loop cycle, up to 999900 cycles |
 |
Selectable test time in seconds,
minutes or hours |
 |
Fast
recovering time, 2 milliseconds |
 |
Line
and load regulation circuits to
provide consistent set output
voltage when input voltage varies
and high inrush current UUT for
example motors an compressors |
 |
Line
and load regulation maintains the
output voltage within 0.5% of
setting |
 |
Capable to withstand inrush current
up to 3 times of rated current |
 |
High
power, compact design and light in
weight |
 |
Built-in PLC remote interface
control, including TEST/RESET and
recall 3 memories setting, P1, P2
and P3. |
 |
Protection circuits for overload,
short circuit and over temperature |
 |
Built-in Input Power Factor
Correction for three phase input
only |
 |
Front
panel software calibration |
 |
Universal output sockets (15A) on
front panel |
 |
Optional GPIB/RS232 Interfaces |
|
 |
 |
 |
|